– Type : Motor type – Installation : Vertical and horizontal – Permissible fluid : Water – Supply Voltage : 220/240VAC
– Allowable fluid temperature : 0~90℃(It shall not be frozen)
– Type : Actuator type – Installation : Free – Permissible fluid : Water – Supply Voltage : 220/240VAC
– Allowable fluid temperature : 0~85℃(It shall not be frozen)
– Type : Motor type – Installation : Free – Permissible fluid : Water – Supply Voltage : 24VDC
– Allowable fluid temperature : 0~60℃(It shall not be frozen)
– Type : Motor type – Operating time : 4 ±2sec – Permissible fluid : Water – Supply Voltage : 12/24VDC
– Allowable fluid temperature : 0~60℃(It shall not be frozen)
– Type : Motorized Three Way ON-OFF Valve type – Connection : Female 15A – Permissible fluid : Water – Supply Voltage : 220/240VAC – Allowable fluid temperature : 0~90℃(It shall not be frozen) – Allowable ambient temperature : 0~60℃ – Operating pressure : 0.2~3 kgf/㎠
– Type : Motorized Three Way ON-OFF Valve type – Connection : Female 25A – Permissible fluid : Water – Supply Voltage : 220/240VAC – Allowable fluid temperature : 0~90℃(It shall not be frozen) – Allowable ambient temperature : 0~60℃ – Operating pressure : 0.2~3 kgf/㎠
– Type : Motorized Three Way Valve type – Installation : Vertical and Horizontal – Permissible fluid : Water – Supply Voltage : 220/240VAC – Allowable fluid temperature : 0~90℃(It shall not be frozen) – Allowable ambient temperature : 0~60℃ – Operating pressure : 0.2~3 kgf/㎠
– Type : Motor type – Installation : Vertical and Horizontal – Permissible fluid : Water – Supply Voltage : 220/240VAC – Allowable fluid temperature : 0~90℃(It shall not be frozen) – Allowable ambient temperature : -10~60℃ – Operating pressure : 0.2~3 kgf/㎠
– Type : Motorized Three Way type – Installation : Free – Permissible fluid : Water – Supply Voltage : 220/240VAC – Allowable fluid temperature : 0~90℃(It shall not be frozen) – Allowable ambient temperature : -10~60℃ – Operating pressure : 0.2~3 kgf/㎠
– Type : Motorized Three Way type – Installation : Free – Permissible fluid : Water – Supply Voltage : 220/240VAC – Allowable fluid temperature : 0~90℃(It shall not be frozen) – Allowable ambient temperature : -10~60℃ – Operating pressure : 0.2~3 kgf/㎠
– Type : Motor type – Installation : Vertical and Horizontal – Permissible fluid : Water – Supply Voltage : 220/240VAC – Allowable fluid temperature : 0~90℃(It shall not be frozen) – Allowable ambient temperature : -10~60℃ – Operating pressure : 0.2~3 kgf/㎠